TTA Bulletin n° 255: IFM Level 1 Renewal Process
EMV® Terminal Type Approval Bulletin No. 255 Fifth Edition April 2024 IFM Level 1 Renewal Process This Bulletin updates the IFM Level 1 renewal testing in v1.0a
Applicability
This Bulletin applies to: Contact Terminal Level 1 Type Approval Process
Related Documents
This Bulletin should be read in conjunction with: “EMV Level 1 Specifications for Payment Systems – EMV Contact Interface Specification”, Version 1.0, October 2022. “EMV SB No. 284 Contact – Clarification for Procedure Byte Use”, 1st Edition, March 2023. “EMV SB No. 298 Contact – Clarification of Terminal Timing for Consecutive Characters”, 1st Edition, September 2023. “EMV – Terminal Type Approval IFM Level 1 – Administrative Process”, version 1.0a, December 2023. “EMV Contact Terminal Level 1 Type Approval – IFM Mechanical and Electrical Test Cases”, version 1.0a, December 2023. “EMV Contact Terminal Level 1 Type Approval – IFM Protocol Test Cases”, version 1.0a, December 2023. “Level 1 IFM – Implementation Conformance Statement”, version 1.0a, December 2023. “EMV Contact Terminal Level 1 Type Approval – Loopback Upper Tester Specification”, version 1.0a, December 2023 EMV Terminal Type Approval Bulletin No.272 – Contact Terminal Level 1 Type Approval v1.0a Release”, First Edition, December 2023 Effective Date Immediately
Description
This Bulletin introduces the Contact Terminal Type Approval renewal for version 1.0a. 1.
Introduction
With the Terminal Type Approval Bulletin No.272, EMVCo introduced the version 1.0a of IFM Level 1 Type Approval process. Accordingly, the present Bulletin introduces the renewal Process for IFMs that were initially approved in version 4.3d or older, and are submitted for renewal testing. As a reminder and as defined in the IFM Administrative Process, renewal testing shall be performed using the applicable version of the Test Plan at the date of starting the renewal tests. _____________________________________________________________________________________________________
countries.
2. v1.0a renewal Since January 1st 2024, the v1.0a test plan is applicable for renewal with the following specific dispositions, that are applicable until January 1st, 2026. 2.1. Electrical Test Cases The Test Case 1CB.013.0x shall be performed with specific conditions during a renewal. As per the Specification Bulletin No. 219, 2nd Edition, October 2022, when the v1.0a acceptance criteria “(4.7MHz – εHz) ≤ CLK average frequency ≤ (5MHz + εHz)” yields a FAIL verdict, the Laboratory shall verify manually the CLK frequency measured by the Test Tool. When the acceptance criteria “(2.8MHz – εHz) ≤ CLK average frequency ≤ (5MHz + εHz)” is met, the Laboratory shall turn the FAIL verdict into a PASS verdict. This final PASS verdict will be accepted as appropriate, whereas a FAIL verdict will lead to the rejection of the renewal, without any possible restricted renewal submission. 2.2. Protocol Test Cases The following Test Cases shall be performed with specific conditions:
- Test Cases 1755.01 to.08 and 1727.20: As per SB-216, these Test Cases shall not be performed and the laboratory shall indicate in the test report that they are N/A, including the following comment: “This test case is not applicable for renewal as per TTA Bulletin 255, 5th Edition”. The reasons for this exception are that IFMs initially approved in v4.3c or older shall accept only an ATR containing TB1 = ’00’, and shall reject an ATR containing TB2.
- Test Cases 1767.230, 1767.240, 1800.112, 1800.212, 1800.113 and 1800.213: As per SB-218, these Test Cases shall not be performed and the laboratory shall indicate in the test report that they are N/A including the following comment: “This test case is not applicable for renewal as per TTA Bulletin 255, 5th Edition”. The reason for this exception is that IFMs initially approved in v4.3c or older shall reject an ATR with 2^CWI = (N + 1).
- Test Cases 1705.DTSxy, 1717.DTSxy and 1727.DTSxy: As per SB-247-2, when the Test Case yields a FAIL verdict that is ONLY due to the intercharacter delay being longer than the maximum inter-character timing, the Laboratory shall change this verdict to PASS. The laboratory shall also add the following comment in the test report: “The verdict has been turned to PASS as per TTA Bulletin 255, 5th Edition”. The reason for this exception is that IFMs initially approved in v4.3c or older had no maximum inter-character timing. 3. General renewal requirements. 3.1. Loopback To start a v1.0a renewal process, an IFM shall include a Loopback Upper Tester application that is compliant to v4.3a, 4.3c, v4.3d or v1.0a. In case an update of the Loopback Upper Tester application is necessary for the renewal testing, no change shall be performed on the Level 1 part of the IFM, neither hardware nor software. countries. 3.2. Applicable Test Cases For the renewal of all IFMs:
- The mechanical tests are not mandatory;
- All the electrical tests are mandatory under all conditions (1);
- All the protocol tests are mandatory. Test Cases Mechanical tests 1CA.00x.0y Electrical tests 1CB.0xx.0y and 1CC.00x.0y Protocol tests Required renewal tests Not mandatory All Test Cases At all temperatures (1) Using all parameters All Test Cases 3.3. Renewal Process The administrative process for renewals remains unchanged. Additional details about the renewal process can be found in the Contact Terminal Level 1 Administrative Process document. For additional information, please contact EMVCo CATA Secretariat. terminal_approval@emvco.com (1) Please note that, as stated in the Test Cases definition, the Test Cases 1CB.001.0x and 1CB.002.0x shall be performed at normal temperature only. countries.
Legal Notice
This document summarizes EMVCo’s present plans for evaluation services and related policies and is subject to change by EMVCo at any time. This document does not create any binding obligations upon EMVCo or any third party regarding the subject matter of this document, which obligations will exist, if at all, only to the extent set forth in separate written agreements executed by EMVCo or such third parties. In the absence of such a written agreement, no product provider, test laboratory or any other third party should rely on this document, and EMVCo shall not be liable for any such reliance. No product provider, test laboratory or other third party may refer to a product, service or facility as EMVCo approved, in form or in substance, nor otherwise state or imply that EMVCo (or any agent of EMVCo) has in whole or part approved a product provider, test laboratory or other third party or its products, services, or facilities, except to the extent and subject to the terms, conditions and restrictions expressly set forth in a written agreement with EMVCo, or in an approval letter, compliance certificate or similar document issued by EMVCo. All other references to EMVCo approval are strictly prohibited by EMVCo. Under no circumstances should EMVCo approvals, when granted, be construed to imply any endorsement or warranty regarding the security, functionality, quality, or performance of any particular product or service, and no party shall state or imply anything to the contrary. EMVCo specifically disclaims any and all representations and warranties with respect to products that have received evaluations or approvals, and to the evaluation process generally, including, without limitation, any implied warranties of merchantability, fitness for purpose or non-infringement. All warranties, rights and remedies relating to products and services that have undergone evaluation by EMVCo are provided solely by the parties selling or otherwise providing such products or services, and not by EMVCo, and EMVCo will have no liability whatsoever in connection with such products and services. This document is provided "AS IS" without warranties of any kind, and EMVCo neither assumes nor accepts any liability for any errors or omissions contained in this document. EMVCO DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT, AS TO THIS DOCUMENT. EMVCo makes no representations or warranties with respect to intellectual property rights of any third parties in or in relation to this document. EMVCo undertakes no responsibility to determine whether any implementation of this document may violate, infringe, or otherwise exercise the patent, copyright, trademark, trade secret, know-how, or other intellectual property rights of third parties, and thus any person who implements any part of this document should consult an intellectual property attorney before any such implementation. Without limiting the foregoing, this document may provide for the use of public key encryption and other technology, which may be the subject matter of patents in several countries. Any party seeking to implement this document is solely responsible for determining whether its activities require a license to any such technology, including for patents on public key encryption technology. EMVCo shall not be liable under any theory for any party's infringement of any intellectual property rights in connection with this document.
countries.